General Introduction

ABB FCB400 Coriolis mass flow meter for high precision measurement of mass flow, volume flow, density, temperature and concentration with low pressure drop. There are two types available, FCB430 with standard accuracy and FCB450 with high accuracy, integrate or remote mount transmitters is optional. For remote mount type, the sensor maximally can meet IP68 with immersion depth five meters under water. For transmitter, both single compartment and dual compartments type are selectable, with standard output protocol Hart, Modbus or Profibus.

2.  Measuring range limits 

Model

FCB430

FCB450

Measuring accuracy for liquids

Mass flow

0.4 %, 0.25 %   and 0.2 %

0.1 % and 0.15 %

Volume flow

0.4 %, 0.25 %   and 0.2 %

0.15 % and 0.11   %

Density

0.01 kg/l

0.002 kg/l, 0.001   kg/l (optional), 0.0005 kg/l

Temperature

1 K

0.5 K

Measuring accuracy for gases

1 %

0.5 %

Approved measuring medium

-50 to 160 °C (-58   to 320 °F)

-50 to 205 °C (-58   to 400 °F):

Process connection

Flange DIN 2501   / EN 1092-1

DN 10 to 200; PN   40 to PN 160

Flange ASME   B16.5

DN ½ to 8 in.;   CL150 to CL1500

JIS flange

DN 10 to 200;   JIS 10K to 20K

Pipe fitting DIN   11851

DN 10 to 100 (􀂡   to 4 in.)

Pipe fitting SMS   1145

DN 25 to 80 (1   to 3 in.)

Tri-clamp DIN   32676 (ISO 2852)

DN 15 to 100 (¼   to 4 in.)

Tri-clamp BPE

DN 3/8 to 4 in.

Female thread DIN ISO 228 and ASME B   1.20.1

DN 15; PN 100

Other   connections

On request

Wetted material

Stainless steel   1.4435 or 1.4404 (AISI 316L), nickel-alloy C4 / C22 (optional)

IP rating

Integral mount   design: IP 65 / IP 67, NEMA 4X

Remote mount   design: IP 65 / IP 67 / IP 68 (sensor only, immersion depth: 5 m), NEMA 4X

Explosion protection

ATEX / IECEx /   cFMus


3.  Transmitter Specification

Housing

Integral mount   design, remote mount design.

IP rating

IP 65 / IP 67,   NEMA 4X

Cable length

Maximum 200 m   (656 ft), remote mount design only

Power supply

100 to 240 V AC,   50 / 60 Hz

11 to 30 V DC,   nominal voltage: 24 V DC

Outputs in basic version

Current output:   4 to 20mA active or passive

Digital output   1: passive, configurable as pulse, frequency or switch output

Digital output   2: passive, configurable as pulse or switch output

Additional optional outputs

The transmitter has two slots in which plug-in cards can be inserted to   provide additional inputs and outputs. The following plug-in cards are   available:

l     Current output (maximum two plug-in cards   simultaneously)

l     Digital output (maximum one plug-in card)

l     Digital input (maximum one plug-in card)

l     Modbus or PROFIBUS DP interface (maximum of one plug-in   card)

l     24 V DC loop power supply for active outputs (maximum   one plug-in card)

External output zero return

Yes

External totalizer reset

Yes

Forward / reverse flow metering

Yes

Counter

Yes

Communication

HART protocol   7.1 Modbus or Profibus DP (using plug-in card)

Empty pipe detection

Yes, via   configurable density alarm

Self-monitoring and diagnosis

Yes

Local indicator

Yes

Field optimization for flow and density

Yes

Concentration measurement ‘DensiMass’

Yes, optional on   models FCB450 and FCH450

‘FillMass’ fill function

Yes, optional on   models FCB450 and FCH450

‘VeriMass’ function

Yes, optional

4.  Flow range and meter tube

Nominal diameter

Qmax in kg/h (lb/h)

Meter tube inside diameter

DN 15 (½ in.)

0 to 8,000 (0 to   17,637)

2 x 8 mm (2 x   0.31 in.)

DN 25 (1 in.)

0 to 35,000 (0   to 77,162)

2 x 16 mm (2 x   0.63 in.)

DN 50 (2 in.)

0 to 90,000 (0   to 198,416)

2 x 23.7 mm (2 x   0.93 in.)

DN 80 (3 in.)

0 to 250,000 (0   to 551,156)

2 x 36.62 mm (2   x 1.44 in.)

DN 100 (4 in.)

0 to 520,000 (0   to 1,146,404)

2 x 52.51 mm (2   x 2.07 in.)

DN 150 (6 in.)

0 to 860,000 (0   to 1,895,975)

2 x 68.9 mm (2 x   2.71 in.)

5.  Model selection of FCB430 and FCB450

Main Code

Suffix Codes

Description

FCB430











CoriolisMaster FCB430 Coriolis Mass   Flowmeter

FCB450











CoriolisMaster FCB450 Coriolis Mass   Flowmeter

Explosion Protection Certification

Y0










General Purpose

A2










ATEX / IECEx (Zone 2 / 22)

A1










ATEX / IECEx (Zone 1 / 21)

F2










cFMus version Class 1 Div. 2 (Zone 2 /   21)

F1










cFMus version Class 1 Div. 1 (Zone 1 /   21)

Connection   Design / Connection Box Material / Cable Glands


Y0









Integral, defined by Transmitter housing


U1









Remote / Aluminium / 1 x M20 x 1.5


U2









Remote / Aluminium / 1 x NPT 1/2 in.


A1









Remote / Stainless Steel / 1 x M20 x 1.5


A2









Remote / Stainless Steel / 1 x NPT 1/2   in.

Meter Size /   Connection Size



015E1








DN 15 (1/2 in.) / DN 10 (3/8 in.)



015R0








DN 15 (1/2 in.) / DN 15 (1/2 in.)



015R1








DN 15 (1/2 in.) / DN 20 (3/4 in.)



025E1








DN 25 (1 in.) / DN 20 (3/4 in.)



025R0








DN 25 (1 in.) / DN 25 (1 in.)



025R2








DN 25 (1 in.) / DN 40 (1-1/2 in.)



050E1








DN 50 (2 in.) / DN 40 (1-1/2 in.)



050R0








DN 50 (2 in.) / DN 50 (2 in.)



050R1








DN 50 (2 in.) / DN 65 (2-1/2 in.)



080E1








DN 80 (3 in.) / DN 65 (2-1/2 in.)



080R0








DN 80 (3 in.) / DN 80 (3 in.)



080R1








DN 80 (3 in.) / DN 100 (4 in.)



100E1








DN 100 (4 in.) / DN 80 (3 in.)



100R0








DN 100 (4 in.) / DN 100 (4 in.)



100R2








DN 100 (4 in.) / DN 150 (6 in.)



150E2








DN 150 (6 in.) / DN 100 (4 in.)



150R0








DN 150 (6 in.) / DN 150 (6 in.)



150R2








DN 150 (6 in.) / DN 200 (8 in.)

Process   Connection Type




D2







Flanges DIN PN 16




D4







Flanges DIN PN 40




D5







Flanges DIN PN 63




D6







Flanges DIN PN 100




S5







Flanges EN 1092-1 PN 40, NAMUR length (DN 15, DN 25, DN 50)




S6







Flanges with groove PN40 EN1092-10-D




S7







Flanges EN 1092-1 PN 16, NAMUR length (DN 100, DN 150)




A1







Flanges ANSI / ASME B16.5 Class 150




A3







Flanges ANSI / ASME B16.5 Class 300




A6







Flanges ANSI / ASME B16.5 Class 600




A7







Flanges ANSI / ASME B16.5 Class 900 (p-t rating Cl 600)




A8







Flanges ANSI / ASME B16.5 Class 1500 (p-t rating Cl 600)




J1







Flanges JIS 10K




J3







Flanges JIS 20K




K1







Sanitary Couplings SMS1145 for pipes acc. DIN11866 Series A




T1







Tri-Clamp acc. DIN 32676




T3







Tri-Clamp acc. BPE




F1







Food industry fittings acc. DIN 11851




N5







Female NPT thread




M5







Female G thread




Z9







Others

Material of   Wetted Parts





A1






Stainless steel





C1






Ni-Alloy

Flow Calibration






A





Flow forward +/- 0.40 % of flow rate, Gas 1 % of flow rate






B





Flow forward +/- 0.25 % of flow rate, Gas 1 % of flow rate






E





Flow forward +/- 0.2 % of flow rate, Gas 1 % of flow rate






C





Forward +/-0.15% of flow rate, Gas 0.5 % of flow rate






D





Forward +/-0.10% of flow rate, Gas 0.5 % of flow rate






J





Flow forward / reverse +/- 0.40 % of flow rate, Gas 1 % of flow rate






K





Flow forward / reverse +/- 0.25 % of flow rate, Gas 1 % of flow rate






N





Flow forward / reverse +/- 0.20 % of flow rate, Gas 1 % of flow rate






L





Flow forward / reverse +/- 0.15 % of flow rate, Gas 0.5 % of flow rate






M





Flow forward / reverse +/- 0.10 % of flow rate, Gas 0.5 % of flow rate






Z





Others

Density Calibration







1




Density 10 g/l







3




Density 2 g/l







4




Density 1 g/l







5




Density 0.5 g/l







9




Others

Connection Design / Transmitter Housing   Type / Transmitter Housing Material / Cable Glands








S1



Integral / Single-compartment / Aluminum / 3 x M20 x 1,5








S2



Integral / Single-compartment / Aluminum / 3 x NPT 1/2 in.








D1



Integral / Dual compartment / Aluminum / 3 x M20 x 1.5








D2



Integral / Dual compartment / Aluminum / 3 x NPT 1/2 in.








D5



Integral / Dual compartment / Aluminum / 3 x NPT 1/2 in. (Exd, XP)








D6



Integral / Dual compartment / Aluminum / 3 x M20 x 1.5 (Exd, XP)








Y0



Remote / Not specified








Z9



Others

Outputs









G0


Current output 1 (active or passive), digital output 1 & 2   (passive), HART









G1


Current output 1 (active or passive), digital output 1 & 2   (passive), 24 V DC transmitter loop power supply, HART









G2


Current output 1 (active or passive), digital output 1 & 2   (passive), current output 2 (passive), HART









G3


Current output 1 (active or passive), digital output 1 & 2   (passive), current output 2 (passive), current output 3 (passive), HART









G4


Current output 1 (active or passive), digitial output 1 & 2   (passive), current output 2 (passive),

24 V DC transmitter loop power supply, HART









M1


Current output 1 (active or passive), digital output 1 & 2   (passive), HART, MODBUS









D1


Current output 1 (active or passive), digital output 1 & 2   (passive), HART, PROFIBUS DP









Y0


Without

Power Supply










A

100 ... 230 V AC










C

11 ... 30 V DC










Y

Without

Optional codes

/Optional codes


6.  Model selection of transmitter FCT430 and FCT450

Main Code

Suffix Codes

Description

FCT430





CoriolisMaster   FCT430 Coriolis Mass Flowmeter Transmitter

FCT450





CoriolisMaster   FCT430 Coriolis Mass Flowmeter Transmitter

Explosion Protection Certification

Y0




General Purpose

A2




ATEX / IECEx (Zone 2 / 22)

A1




ATEX / IECEx (Zone 1 / 21)

F2




cFMus version Class 1 Div. 2 (Zone 2 /   21)

F1




cFMus version Class 1 Div. 1 (Zone 1 /   21)

Connection Design / Transmitter Housing   Type / Transmitter Housing Material / Cable Glands


W1



Remote / Single-compartment / Aluminum /   4 x M20 x 1.5


W2



Remote / Single-compartment / Aluminum /   4 x NPT 1/2 in.


R1



Remote / Dual compartment, wall mounted   / Aluminum / 4 x M20 x 1.5


R2



Remote / Dual compartment, wall mounted   / Aluminum / 4 x NPT 1/2 in.


R5



Remote / Dual compartment, wall mounted   / Aluminum / 4 x M20 x 1.5 (Exd, XP)


R6



Remote / Dual compartment, wall mounted   / Aluminum / 4 x NPT 1/2 in. (Exd, XP)


Z9



Others

Outputs



G0


Current output 1 (active or passive),   digital output 1 & 2 (passive), HART



G1


Current output 1 (active or passive),   digital output 1 & 2 (passive), 24 V DC transmitter loop power supply,   HART



G2


Current output 1 (active or passive),   digital output 1 & 2 (passive), current output 2 (passive), HART



G3


Current output 1 (active or passive), digital output 1 & 2   (passive), current output 2 (passive), current output 3 (passive), HART



G4


Current output 1 (active or passive), digital output 1 & 2   (passive), current output 2 (passive), 24 V DC transmitter loop power supply,   HART



M1


Current output 1 (active or passive),   digital output 1 & 2 (passive), HART, MODBUS



D1


Current output 1 (active or passive),   digital output 1 & 2 (passive), HART, PROFIBUS DP



Z9


Others

Power Supply




A

100 ... 230 V AC




C

11 ... 30 V DC

Optional codes

/Optional codes